Document Reference No.: ES_000008
S1-A-7001 RS232 to 1-Port CANbus Adapter User Guide
Version 1.2
Clearance No.: ES #03
©2009-10 EasySync Ltd. 11
4.1.1 Help (H, h or ?)
Summary
Lists available commands.
Definition
H<CR>, h<CR> or ?<CR>
Parameters
None
Remarks
Example:
?<CR>
List available commands.
Return Codes
List of Supported Commands
O - Open CAN Channel
C - Close CAN Channel
t - Transmit Standard Frame
T - Transmit Extended Frame
F - Read Status Flag
V S1-A-7001 Version
N - Serial Number of S1-A-7001
Z - TimeStamp Option On/Off
S - Set CAN Bit Rate
s - Set BRGCON Registers
m - Set Acceptance Mask
M - Set Acceptance Filter
B - Enter Bootload Mode
L - Set Listen Mode
E - Clear Buffers and Echo Char
R - Reset S1-A-7001
U Set UART Baud Rate
H, ? or h - Help on S1-A-7001 Commands
<CR> = OK